Products Brands
0
0 IDR0
Your shopping cart is empty!
Milwaukee MW102 PRO+ 2-in-1 pH and Temperature Meter with ATC

Milwaukee MW102 PRO+ 2-in-1 pH and Temperature Meter with ATC

IDR0
-+
Code: MW102 PRO
Brand: Milwaukee
Category: > PH Meter
Description:

DESIGN FEATURES

  • Fast easy to read results with large digital LCD readout
  • Extreme accuracy to ±0.02 pH and extended range (-2.00 pH to 16.00 pH)
  • Lightweight and portable
  • Easy measurement: just place the probe in the sample, gently stir and wait for the reading to stabilize
  • Simple push button, automatic two-point calibration for increased accuracy
  • Gel-filled, double junction lab grade pH electrode for low maintenance and high performance with a screw on cap to ensure proper storage
  • Rugged stainless temperature probe
  • 3 feet probe cables for extra flexibility when testing
  • Auto shut off and low power demand with approx. 300 hours of continuous use (battery included)

CARE AND USE 

pH meters usually start performing poorly because of problems with the probe. The two parts of the pH probe that cause problems are the glass sensing bulb and the reference junction.

SENSING BULB

The glass bulb loses sensitivity with use and will eventually fail. This is true of all pH probes.

REFERENCE JUNCTION

The reference junction is a small hole that allows the meter to compare the sample to a reference. The reading is generated based on the electrical difference between the sample and reference. If the junction hole gets clogged, the pH electrode will no longer function.

You can extend the life of your pH electrode in the following ways.

CLEANING AND STORAGE

All pH sensors have a limited life and response time gets longer with age. Properly maintaining your pH pen tester will give you fast, accurate results for longer. So, be sure to order the Milwaukee pH Maitenance Kit code PH-Main at checkout time!  This will be needed to help clean and condition the pH electrode before use!

STORAGE

The pH probe needs to be kept hydrated. Long periods of dry storage will damage the sensitivity of the probe. Allowing the probe to dry out may also result in the junction hole getting clogged.

Storing in pH probe storage solution MA9015 or pH calibration buffers will help address both these issues. Do not store in tap water and DI water. This will damage the sensitivity of the probe.

The best way to store the probe is with the probe's cap filled with storage solution or calibration buffer and the cap tightened to prevent leakage. It is also recommended that to store the electrode upright to further reduce the potential for leakage.

CLEANING

Residue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution MA9016.

CALIBRATION

The pH sensing bulbs become less sensitive over time so make sure that you are calibrating regularly to keep your PRO Plus pH meter accurate. Also, calibrate after cleaning or a long period of storage.

SPECIFICATIONS

  • pH Range: -2.00 to 16.00 pH
  • Temp Range: -5 to 70°C
  • pH Accuracy ±0.02 pH
  • pH Resolution: 0.01 pH
  • pH Typical EMC Deviation: ±0.2 pH
  • Temp Resolution 0.1°C
  • Temp Accuracy (@25°C): ±0.5°C
  • Temperature Compensation: Automatic, 0 to 70°C
  • Temp Typical EMC Deviation: ±0.5°C
  • Calibration: Automatic, 1 or 2 points
  • pH Electrode: SE220 (included)
  • Temperature: Probe MA831R (included)
  • Environment: 0 to 50°C / 32 to 122°F; max RH 95%
  • Battery Type: 1 x 9V (included)
  • Battery Life: Approx. 300 hours of continuous use
  • Auto-off: After 8 minutes of non-use
  • Approximate dimensions: 5.7 x 3.1 x 1.6 inches
  • Weight: 1.1 lbs with battery